Official website

Doména gov.sk je oficálna

Toto je oficiálna webová stránka orgánu verejnej moci Slovenskej republiky. Oficiálne stránky využívajú najmä doménu gov.sk. Odkazy na jednotlivé webové sídla orgánov verejnej moci nájdete na tomto odkaze.

This page is secured

Buďte pozorní a vždy sa uistite, že zdieľate informácie iba cez zabezpečenú webovú stránku verejnej správy SR. Zabezpečená stránka vždy začína https:// pred názvom domény webového sídla.

  1. Home
  2. STN EN ISO 4037-3

STN EN ISO 4037-3

Back

Electronic version (pdc file)

Add to Cart
Name: STN EN ISO 4037-3
Validity: Valid
Number of pages: 80
Language:
EN
Paper: 28,80€
Electronic version a) Only read (without ability to print and copy) 25,92€
b) Without ability to print, with ability to copy (printscreen) 28,80€
c) With ability to print and copy (printscreen) 37,44€
Slovak title Rádiologická ochrana. X a gama referenčné žiarenie na kalibráciu dozimetrov a dávkomerov a na stanovenie ich odozvy ako funkcie energie fotónov. Časť 3: Kalibrácia priestorových a osobných dozimetrov a meranie ich odozvy ako funkcie energie a uhla dopadu (ISO 4037-3: 2019)
English title Radiological protection - X and gamma reference radiation for calibrating dosemeters and doserate meters and for determining their response as a function of photon energy - Part 3: Calibration of area and personal dosemeters and the measurement of their response as a function of energy and angle of incidence (ISO 4037-3:2019)
Release Date: 01. 08. 2021
Date of withdrawal:
ICS: 17.240
Sorting character/National clasification code 40 1413
Level of incorporation: idt ISO 4037-3:2019, idt EN ISO 4037-3:2021
Official Journal 07/21
Amendments
Replaced by:
Repleces:
Note in Official Journal:
Subject of the standard: This document specifies additional procedures and data for the calibration of dosemeters and doserate meters used for individual and area monitoring in radiation protection. The general procedure for the calibration and the determination of the response of radiation protection dose(rate)meters is described in ISO 29661 and is followed as far as possible. For this purpose, the photon reference radiation fields with mean energies between 8 keV and 9 MeV, as specified in ISO 4037-1, are used. In Annex D some additional information on reference conditions, required standard test conditions and effects associated with electron ranges are given. For individual monitoring, both whole body and extremity dosemeters are covered and for area monitoring, both portable and installed dose(rate)meters are covered. Charged particle equilibrium is needed for the reference fields although this is not always established in the workplace fields for which the dosemeter should be calibrated.
Preview: Náhľad normy (PDF)