Official website

Doména gov.sk je oficálna

Toto je oficiálna webová stránka orgánu verejnej moci Slovenskej republiky. Oficiálne stránky využívajú najmä doménu gov.sk. Odkazy na jednotlivé webové sídla orgánov verejnej moci nájdete na tomto odkaze.

This page is secured

Buďte pozorní a vždy sa uistite, že zdieľate informácie iba cez zabezpečenú webovú stránku verejnej správy SR. Zabezpečená stránka vždy začína https:// pred názvom domény webového sídla.

  1. Home
  2. STN EN IEC 61643-11

STN EN IEC 61643-11

Back

Electronic version (pdc file)

Add to Cart
Name: STN EN IEC 61643-11
Validity: Valid
Number of pages: 48
Language:
EN
Paper: 18,90€
Electronic version a) Only read (without ability to print and copy) 17,01€
b) Without ability to print, with ability to copy (printscreen) 18,90€
c) With ability to print and copy (printscreen) 24,57€
Slovak title Nízkonapäťové prepäťové ochranné prístroje. Časť 11: Prepäťové ochranné prístroje zapojené v sieťach nízkeho napätia striedavého prúdu. Požiadavky a skúšobné metódy
English title Low-voltage surge protective devices - Part 11: Surge protective devices connected to AC low-voltage power systems - Requirements and test methods
Release Date: 01. 04. 2026
Date of withdrawal:
ICS: 29.240.10
Sorting character/National clasification code 34 1395
Level of incorporation: idt EN IEC 61643-11:2025, idt IEC 61643-11:2025
Official Journal 03/26
Amendments Zmena A11 V 03/26
Replaced by:
Repleces: STN EN 61643-11:2013-08 (34 1395)
Note in Official Journal:
Subject of the standard: IEC 61643-11:2025 is applicable to devices for surge protection against indirect and direct effects of lightning or other transient overvoltages. These devices are intended to be connected to AC power circuits and equipment rated up to 1 000 V RMS, the preferred frequencies taken into account in this document are 50/60 Hz. Other frequencies are not excluded. Performance and safety requirements, tests and ratings are specified in this document. These devices contain at least one nonlinear component and are intended to limit surge voltages and divert surge currents. The test requirements provided by this document are based on the assumption that the SPD is connected to an AC power circuit fed by a power source providing a linear voltage-current characteristic. When the SPD is to be connected to a different kind of source or to a different frequency, careful consideration is required. This mainly applies with regard to system and fault conditions to be expected in such a system (e.g. expected short ...
Preview: Náhľad normy (PDF)