Official website

Doména gov.sk je oficálna

Toto je oficiálna webová stránka orgánu verejnej moci Slovenskej republiky. Oficiálne stránky využívajú najmä doménu gov.sk. Odkazy na jednotlivé webové sídla orgánov verejnej moci nájdete na tomto odkaze.

This page is secured

Buďte pozorní a vždy sa uistite, že zdieľate informácie iba cez zabezpečenú webovú stránku verejnej správy SR. Zabezpečená stránka vždy začína https:// pred názvom domény webového sídla.

  1. Home
  2. STN EN IEC 60749-24

STN EN IEC 60749-24

Back

Electronic version (pdc file)

Add to Cart
Name: STN EN IEC 60749-24
Validity: Valid
Number of pages: 16
Language:
EN
Paper: 14,10€
Electronic version a) Only read (without ability to print and copy) 12,69€
b) Without ability to print, with ability to copy (printscreen) 14,10€
c) With ability to print and copy (printscreen) 18,33€
Slovak title Polovodičové súčiastky. Mechanické a klimatické skúšobné metódy. Časť 24: Zvýšená odolnosť proti vlhkosti. HAST bez elektrického namáhania
English title Semiconductor devices - Mechanical and climatic test methods - Part 24: Accelerated moisture resistance - Unbiased HAST
Release Date: 01. 04. 2026
Date of withdrawal:
ICS: 31.080.01
Sorting character/National clasification code 35 8799
Level of incorporation: idt EN IEC 60749-24:2026, idt IEC 60749-24:2025
Official Journal 03/26
Amendments
Replaced by:
Repleces: STN EN 60749-24:2004-10 (35 8799)
Note in Official Journal:
Subject of the standard: IEC 60749-24:2025 specifies unbiased highly accelerated stress testing (HAST). HAST is performed for the purpose of evaluating the reliability of non-hermetically packaged solid-state devices in humid environments. It is a highly accelerated test which employs temperature and humidity under non-condensing conditions to accelerate the penetration of moisture through the external protective material (encapsulant or seal) or along the interface between the external protective material and the metallic conductors which pass through it. Bias is not applied in this test to ensure that the failure mechanisms potentially overshadowed by bias can be uncovered (e.g. galvanic corrosion). This test is used to identify failure mechanisms internal to the package and is destructive. This edition includes the following significant technical changes with respect to the previous edition: a) rearrangement of clauses to reposition requirements; b) addition of two notes to the post-test electrical procedures.
Preview: Náhľad normy (PDF)