Official website

Doména gov.sk je oficálna

Toto je oficiálna webová stránka orgánu verejnej moci Slovenskej republiky. Oficiálne stránky využívajú najmä doménu gov.sk. Odkazy na jednotlivé webové sídla orgánov verejnej moci nájdete na tomto odkaze.

This page is secured

Buďte pozorní a vždy sa uistite, že zdieľate informácie iba cez zabezpečenú webovú stránku verejnej správy SR. Zabezpečená stránka vždy začína https:// pred názvom domény webového sídla.

  1. Home
  2. STN EN 50488

STN EN 50488

Back

Electronic version (pdc file)

Add to Cart
Name: STN EN 50488
Validity: Withdrawn
Number of pages: 40
Language:
EN
Pripravuje sa preklad do slovenského jazyka. Pre viac informácií nás kontaktujte na navrhynoriem@normoff.gov.sk
Paper: 18,90€
Electronic version a) Only read (without ability to print and copy) 17,01€
b) Without ability to print, with ability to copy (printscreen) 18,90€
c) With ability to print and copy (printscreen) 24,57€
Slovak title Dráhové aplikácie. Pevné inštalácie. Elektrické ochranné opatrenia pre pracovné činnosti na systémoch nadzemného trolejového vedenia alebo v ich blízkosti alebo na súvisiacom spätnom okruhu
English title Railway applications - Fixed installations - Electrical protective measures for working on or near an overhead contact line system and/or its associated return circuit
Release Date: 01. 05. 2021
Date of withdrawal: 01. 08. 2024
ICS: 13.260, 45.020
Sorting character/National clasification code 34 1506
Level of incorporation: idt EN 50488:2021
Official Journal 04/21
Amendments
Replaced by: STN EN 50488:2024-08 (34 1506)
Repleces: TNI CLC/TR 50488:2008-04 (34 1506)
Note in Official Journal:
Subject of the standard: This document provides requirements for electrical safety for: - dead working on an overhead contact line system; - working activities near an overhead contact line system when it is live. It applies to all work activities in relation to electrical hazards only. This document is applicable to overhead contact line systems with the following nominal voltages: - 1,5 kV and 3 kV dc; - 15 kV, 2x15 kV, 25 kV and 2x25 kV ac. It also provides requirements for work activities that can give rise to electrical hazards from the return circuit. This document does not cover electrical risk arising from: - live working on overhead contact line systems (live working can be carried out according to national requirements and practices); - working on or near other electrical sources. If there are no other rules or procedures, this document could be applied to overhead contact line systems with other nominal voltages.
Preview: Náhľad normy (PDF)